LG Water Solutions,LG Chem

LG BW 400 AFR

    Anti-Fouling, High Rejection |

     

    LG BW 400 AFR membranes offer a combination of enhanced fouling resistance and high rejection: suitable for brackish water and water reuse applications with a challenging feed water.

Product Specifications
Active Membrane Area 400 ft² (37 m²)
Permeate Flow Rate 10,500 gpd (39.7 m³/d)
Stabilized Salt Rejection 99.6%
Minimum Salt Rejection 99.5%
Feed Spacer 34 mil
Test Conditions
NaCl 2,000 ppm
Pressure 225 psi (15.5 bar)
Temperature 25°C (77°F)
pH 7
Recovery 15%
Permeate Flow Variation +25/-15%
Operating Specifications
Max. Operating Pressure 600 psi (41 bar)
Max. Chlorine Concentration <0.1 ppm
Max. Operating Temperature 45°C (113°F)
pH Range, Continuous (Cleaning) 2-11 (2-12)
Max. Feedwater Turbidity 1.0 NTU
Max. Feedwater SDI (15 minutes) 5.0
Max. Feed Flow 75 gpm (17 m³/h)
Max. Pressure Drop for Each Element 15 psi (1.0 bar)
Product Dimensions
Length 1,016 mm (40 inch)
Element O.D. 200 mm (7.9 inch)
Permeate Tube I.D. 28.6 mm (1.125 inch)
Weight 16 kg (35 lbs.)