LG Chem Water Solutions develops, manufactures and markets the next generation of BWRO elements for water treatment. We offer industry-standard 8-inch and 4-inch element configurations that retrofit easily into standard pressure vessels. Click on each model number below for detailed product information.

Model Number Membrane Area Element Diameter Permeate Flow Rate Stabilized
NaCl Rejection
Feed Spacer
LG BW 400 ES1 37 m2 (400 ft2) 20 cm (8 in) 39.7 m3/d (10,500 gpd) 99.6% 34 mil
LG BW 440 ES1 41 m2 (440 ft2) 20 cm (8 in) 43.7 m3/d (11,500 gpd) 99.6% 28 mil
LG BW 4040 ES3 7.9 m2 (85 ft2) 10 cm (4 in) 9.5 m3/d (2,500 gpd) 99.5% 28 mil
LG BW 400 R2 37 m2 (400 ft2) 20 cm (8 in) 39.7 m3/d (10,500 gpd) 99.6% 34 mil
LG BW 440 R2 41 m2 (440 ft2) 20 cm (8 in) 43.7 m3/d (11,500 gpd) 99.6% 28 mil
LG BW 4040 R3 7.9 m2 (85 ft2) 10 cm (4 in) 9.5 m3/d (2,500 gpd) 99.6% 28 mil
LG BW 400 AFR2 37 m2 (400 ft2) 20 cm (8 in) 39.7 m3/d (10,500 gpd) 99.6% 34 mil
LG BW 4040 AFR3 7.4 m2 (80 ft2) 10 cm (4 in) 8.7 m3/d (2,300 gpd) 99.6% 34 mil

NOTE:

  • 1. The above values are normalized to the following test conditions: 2,000 ppm NaCI, 10.3 bar (150 psi), 25°C(77°F), pH 8, 15% recovery. Permeate flows for individual elements may vary -/+ 15%.
  • 2. The above values are normalized to the following test conditions: 2,000 ppm NaCI, 15.5 bar (225 psi), 25°C(77°F), pH 8, 15% recovery. Permeate flows for individual elements may vary -/+ 15%.
  • 3. The above values are normalized to the following conditions: 2,000 ppm NaCl, 15.5 bar (225 psi), 25°C (77°F), pH 6.5 – 7.0, 15% recovery. Permeate flows for individual elements may vary +/- 20%.